Ultrasonic Flowmeters

  • Ultrasonic Flowmeter for Steam (FSJ)
  • Spool Piece Ultrasonic Flowmeter (FST)
  • Portable Ultrasonic Flowmeter (FSC)
  • TIME DELTA-C (FSV)
  • TIME DELTA-C advanced type (FSVL)
  • M-Flow PW (FLR)
  • Ultrasonic Flowmeter for Air (FWD)

Pressure Transmitters and Differential Pressure Transmitters

  • FCX-AIII Series Transmitters
  • Equalizing Valve, Oval Flange (FFN, FFP)
  • Hand-Held Communicator (FXW)
  • Orifice Plates

Level Transmitters

  • Water Level Transmitter (FQK)
  • FCX-AIII Series Level Transmitter (FKE-5)

Temperature Controllers

  • Digital Temperature Controller (PXF )
  • Digital Temperature Controller (PXR3)
  • Digital Temperature Controller (PXE)
  • Digital Controller (PXH)
  • Module Type Temperature Controller
  • Digital Thermostat (PXR3)

Gas Analyzers

  • Flue Gas Analyzer System
  • Cross Stack Laser Gas Analyzer
  • Aerosol Analyzer
  • In-Situ Zirconia Oxygen Analyzer System
  • Double Beam NDIR Gas Analyzer
  • Single Beam NDIR Gas Analyzer
  • Thermal Conductivity Gas Analyzer
  • Flameproof Thermal Conductivity Gas Analyzer
  • Paramagnetic Oxygen Analyzer
  • In-Situ Zirconia Oxygen Analyzer HART Communication, Hazardous Location
  • Compact NDIR Gas Analyzer System
  • Portable NDIR Gas Analyzer
  • NDIR Gas Analyzer for Heat Treatment Furnaces
  • NDIR CO2 Controller
  • Biomass Gas Analyzer
  • Gas Sampling Devices
Ultrasonic Flowmeters

Easy and accurate flow measurement without interrupting the process

Clamp-on type sensor easily mountable on existing pipe Suited for a wide range of liquids, for example, deionized water, cooling water, chemical solution, drinking water, sea water, oil, tap water, hot water, industrial water, corrosive liquids.

Ultrasonic flowmeter for air is also available

Ultrasonic Flowmeter
  • Clamp-on type saturated steam flow measurements
  • No Plumbing Required
  • No Pressure Loss
  • Less Maintenance Cost
  • Measurements at low flow rates
  • Three pairs of sensors for accuracy of ±0.2% of rate
  • Ex-proof version available
  • Accuracy 0.2% of rate
  • Analog, pulse, alarm output
  • ø 50, 80, 100 mm
  • Hart or RS-485
  • Ideal for multi-point measurement in the field
  • Battery-powered 12 hours
  • SD Card
  • Flow Profile (option)
  • Printer (option)
  • Accuracy 1.0% of rate
  • Analog, pulse, alarm output
  • ø 13 - 16000 mm
  • RS-485 (option)
  • Offers consumed energy calculation, 2 pipe measurement, 2-path measurement for 1 pipe
  • Energy Calculation
  • Dual Channel Math function
  • 2-path for 1 pipe
  • RS-485 (option)
  • Compact transmitter
  • For pipes ø25–ø1200 mm
  • Accuracy 1.5% of rate
  • Compact design
  • ø 25-1200 mm
  • RS-485 (option)
Ultrasonic Flowmeter for Air (FWD)
  • For pipes ø25–ø1200 mm
  • No pressure loss
  • Battery-powered or 24 V DC
  • Flow rate conversion
  • Forward/reverse flow
Pressure Transmitters and Differential Pressure Transmitters

For highly precise and accurate measurement of pressure, differential pressure, and flow rate

Fuji Electric has long delivered electronic transmitters, incorporating the micro-capacitance silicon sensor, to our customers worldwide.

The FCX-AIII series transmitters feature compact design, high accuracy and performance, long-term stability. They also offer wide measuring ranges and provide a variety of diaphragm materials.

Pressure Transmitters and Differential Pressure Transmitters
FCX-AIII Series Transmitters
  • Long-term stable measurement of pressure or differential pressure (flow rate)
Equalizing Valve, Oval Flange (FFN, FFP)
  • For the use with differential pressure transmitters
  • 16 Mpa or 42 Mpa
  • With pressure tube
Hand-Held Communicator (FXW)
  • For communication with transmitters
  • 16-digit 4-Line LCD
  • Rechargeable
  • Printer (option)
Orifice Plates
  • Designed according to JIS standards
Level Transmitters

Level Transmitters

Water Level Transmitter

FCX-AIII Series Level Transmitter

Level Transmitters
Water Level Transmitter (FQK)
  • Continuously measures a water level up to 50 m
  • ±0.2%
  • For sweage water
  • Powerful arrester
  • 4-20 mA DC 2-wire
FCX-AIII Series Level Transmitter (FKE-5)
  • Flange type level transmitter
  • Measuring span: 0.32–500 kPa
  • ±0.2%
  • Corrosion resistant
  • Ex-proof
  • 24 V DC 2-wire
Temperature Controller

Key to optimal temperature control

We offer a wide variety of temperature controllers to meet your needs.

Explore our products and find the best for your application.

Our latest temperature controller PXF has won the Good Design Award 2017. (hosted by the Japan Institute for Design Promotion)

Temperature Controller
  • Versatile controller with bright and clear color LCD
  • Socket type available
  • Color LCD
  • Fast response ≤50 ms
  • Universal input
  • 58-mm depth
Digital Temperature Controller (PXR3)
  • *PXR4, PXR5, PXR7, and PXR9 were discontinued and replaced by PXF series. Only PXR3 is available.
  • Versatile model with easy-to-see LED, transfer output, communication function, and more.
  • Standard modal
  • 2 alarm outputs
  • 24 x 48 mm
  • 98-mm depth
Digital Temperature Controller (PXE)
  • Simple and compact
  • Simple
  • Easy-to-operate
  • 48 x 48 mm
  • 62-mm depth
  • Various inputs and outputs
  • Highly precise and fast control
  • 96 x 96 mm size
  • High accuracy 0.1%
  • 5-Digit display
  • Math function
  • DI (9), D0 (9), AI (2)
  • Rail-mount, multi-loop temperature controller comprised of control module, I/O module, and communication module
  • 4 channel's for each module
  • Programless communication
  • Extensive Line-up
  • Datachable terminal
Digital Thermostat (PXR3)
  • Detects overheat of thermocouples or thermistors used in various machines or equipment.
  • Reasonably priced
  • 24 x 48 mm
  • Rail amount (option)
  • 2 alarm outputs
Gas Analyzers

Analyzing air pollution is the first step toward preserving a clean atmospheric environment.

FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.

Gas Analyzers
Flue Gas Analyzer System (ZSU) NOx, SO2, CO, CO2, O2
  • Double-beam NDIR sensor + O2 sensor
  • Long-term stability
  • Continuous measurement of up to 5 components
  • 5 components
  • JP type approval
  • Easy maintenance
  • Auto calibration
Flue Gas Analyzer System (ZSJ) NOx, SO2, CO, CO2, O2
  • Single-beam NDIR sensor with sample switching system + O2 sensor
  • Excellent zero-point stability
  • Continuous measurement of up to 5 components
  • 5 components
  • JP type approval
  • Easy maintenance
  • Driftless
Flue Gas Analyzer System (ZSU-7) NOx, SO2, CO, CO2, O2, HCl, dust
  • Monitors up to 7 gas concentrations
  • Space-saving design
  • 7 components
  • Space saving
  • Easy maintenance
  • Less wiring work
Cross Stack Laser Gas Analyzer (ZSS) HCl, NH3, O2, CO, CO2, CH4
  • Direct insertion type
  • Continuous measurement of HCl, NH3, O2, CO, CO2, and CH4 in flue gas
  • Fast response ≤ 2 s
  • In situ
  • CO+O2 measurementLong-term stability
Aerosol Analyzer (ZSF)
  • Real-time and quantitative analysis of particle size, number of particles, composition (sulfate, nitrate, black carbon) of aerosol (PM2.5) in the air
  • Real-time analysis ≤ 15 min
  • PM. 5
  • Black carbon, sulfate, nirate
  • High precision
In-Situ Zirconia Oxygen Analyzer System (ZSB)
  • Continuous measurement of O2 in combustible gas
  • Ideal for combustion control
  • Fast response ≤ 10 s
  • Insertion type
  • Auto calibration
  • Blow down
Double Beam NDIR Gas Analyzer (ZKJ) NO, SO2, CO, CO2, N2O, CH4, O2
  • Double-beam NDIR sensor
  • Continuous measurement of up to 5 components
  • 5 Components 0-20 ppm
  • Double beam NDIR
  • Auto calibration
  • Rangeability 1:25
Single Beam NDIR Gas Analyzer (ZPA) NO, SO2, CO, CO2, CH4, O2
  • Single-beam NDIR sensor
  • Compact and light weight
  • Continuous measurement of up to 5 components
  • 5 Components 0-200 ppm
  • Single beam NDIR
  • Auto calibration
  • Rangeability 1:10
Single Beam NDIR Gas Analyzer (ZPB) NO, SO2, CO, CO2, O2
  • Single-beam NDIR sensor with sample-switching system
  • Continuous measurement of up to 5 components
  • 5 Components 0-50 ppm
  • Sample-switching
  • Auto calibration
  • Driftless
Single Beam NDIR Gas Analyzer (ZPG) NO, SO2, CO, CO2, O2
  • Single-beam NDIR sensor with sample-switching system
  • Continuously measures low concentration (0–5 ppm) gases
  • Low range 0-5 ppm
  • Sample-switching
  • Auto calibration
  • Driftless
Single Beam NDIR Gas Analyzer (ZRE) NO, SO2, CO, CO2, O2
  • Single-beam NDIR sensor
  • Compact and light weight
  • Continuous measurement of up to 5 components
  • 5 Components 0-200 ppm
  • Single beam NDIR
  • Auto calibration
  • Rangeability 1:10
Thermal Conductivity Gas Analyzer (ZAF) H2, He, Ar
  • Best suited for H2, He, and Ar measurement
  • Easy-to-see LCD
  • Auto calibration
  • Fast response ≤ 10 s
  • Interference compensation
Flameproof Thermal Conductivity Gas Analyzer (ZAFE)
  • Ideal for H2, Ar, and He measurement
  • NEPSI flameproof
  • Easy-to-see LCD
  • Auto calibration
  • Fast response ≤ 10 s
Paramagnetic Oxygen Analyzer (ZAJ)
  • Fast response
  • Communication function
  • Ideal for measuring oxygen in combustible gas
  • Fast response ≤ 10 s
  • Auto calibration
  • Combustible gas
  • Unaffected by combustible gas
Paramagnetic Oxygen Analyzer (ZKG)
  • Fast response ≤ 15 s
  • Noauxiliary gas required
  • Combustible gas
  • JP type approval
In-Situ Zirconia Oxygen Analyzer (ZKM1, ZKM2, ZFK8)
  • Insertion type
  • No need for gas sampling device
  • Measures O2 in incombustible gas
  • Fast response ≤ 7 s
  • Replaceable sensor
  • Non-combustible gas
  • Auto calibration
In-Situ Zirconia Oxygen Analyzer (HART Communication) (ZKMA, ZKMB, ZFK8)
  • In-situ oxygen analysis requires no gas sampling device
  • Ideal for combustion control in industrial boilers and furnaces
  • Fast response ≤ 7 s
  • Replaceable sensor
  • Non-combustible gas
  • HART communication
In-Situ Zirconia Oxygen Analyzer for Hazardous Location (ZKME, ZFKE)
  • Insertion type
  • No need for gas sampling device
  • Measures O2 in incombustible gas
  • Fast response ≤ 7 s
  • Replaceable sensor
  • TIIS & NEPSI flamepoof
  • Auto calibration
Compact NDIR Gas Analyzer System (ZSVF)
  • Simultaneously measures up to 5 components among NOx, SO2, CO, CO2, CH4, and O2
  • No need for gas sampling device
  • Compact design
  • Sampling system incorporated
  • 3 components
  • Auto calibration
Portable NDIR Gas Analyzer (ZSVS)
  • Simultaneously measures up to 4 components among CO, CO2, CH4, and O2
  • Portable
  • Built-in pump
  • 4 components
  • CP calculation
NDIR Gas Analyzer for Heat Treatment Furnaces (ZFG)
  • Continuous measurement of CO, CO2, CH4 in heat treatment furnace
  • Panel mount
  • Single beam NDIR
  • 4 components
  • CP calculation
NDIR CO2 Controller (ZFP)
  • Measures CO2 in the air
  • Analog output and alarm output
  • Wall mount
  • Built-in pump
  • 4-20 mA DC output
  • Limit alarm
Biomass Gas Analyzer (ZPAF)
  • Measures H2S, CH4, CO2, and O2 generated in biogas plants
  • 4 components
  • H2S, CH4, CO2, O2
  • Auto calibration
  • Alarm output
NDIR Gas Analyzer (Substitute for ZRG) (ZKJJ)
  • Double-beam NDIR sensor
  • Compatible to obsoleted ZRG
  • 3 components 0-100 PPM
  • Double beam NDIR
  • Auto calibration
  • Rangeability 1:25
NDIR Gas Analyzer (Substitute for ZRH)
  • Single-beam NDIR sensor
  • Compatible to obsolated ZRH
  • 2 components
  • Single beam NDIR
  • Auto calibration
  • Rangeability 1:10
NDIR Gas Analyzer (Substitute for ZRJ) (ZPAJ)
  • Single-beam NDIR sensor
  • Compatible to obsolated ZRJ
  • 3 components
  • Single beam NDIR
  • Auto calibration
  • Rangeability 1:10
Gas Sampling Devices (ZB, ZDL)
  • Gas extractor, pump, cooler, filter, converter, etc.
  • Standard gas
  • Scrubber
  • Mist catcher
  • Gas dryer
Industries We Serve
  • Oil & Gas Sector
  • Chemical Industry
  • Pharmaceutical Industry
  • Water Treatment Industry
  • Paper Pulp industry
  • Fertilizer Industry
  • Food Processing Companies
  • Engineering Works
  • Fabricators
  • Shipbuilding & Marine
  • Steam & Power Generation
  • Refrigeration & Air Conditioning
Send Enquiry